Exploration Precision Industry (Qingdao) Co., Ltd. · A Leader in Cleanroom Building Systems Consultation Hotline +86 532 66667956 中文
Product Systems / HVAC

HVAC

Cleanroom HVAC systems including air-handling units, FFUs, exhaust fans, duct dampers, ductwork and filtration configurations to maintain cleanliness, airflow organization and stable pressure differentials.

Systems & Equipment

By System Stage

Cleanroom HVAC design must coordinate outdoor-air load, supply/return air, process exhaust, airflow organization and pressure gradients. The following are core equipment types; final configurations are calculated from process parameters.

01 / Air Handling Unit

Cleanroom Air Handling Unit (AHU)

Integrates pre-/medium-efficiency filtration, heating, humidification, cooling and dehumidification to supply conditioned air to clean areas.

Airflow RangeCalculated per project load
FiltrationPre + Medium + Semi-HEPA
Control MethodVFD + Automatic Controls
02 / FFU

FFU Fan Filter Unit

Integrates a fan and high-efficiency filter for direct ceiling installation and terminal supply in ISO 5-7/8 clean areas.

Filter EfficiencyH13 / H14
Cleanroom ClassISO 5-8/GMP A-D
InstallationCeiling recessed
03 / Exhaust Fans

Cleanroom Exhaust Fans

For process exhaust, general exhaust and local extraction systems in clean facilities. Axial, centrifugal or mixed-flow fans are selected to suit airflow, total pressure, noise and installation conditions.

Fan TypeAxial / Centrifugal / Mixed-flow
Airflow & PressureSelected by system calculation
ControlDirect start / VFD interlock
04 / Duct Dampers

Fire / Volume-Control & Other Duct Dampers

A dedicated duct-damper category covering fire dampers, smoke-exhaust fire dampers, manual/electric volume-control dampers and backdraft dampers for fire separation, airflow balancing and system interlocking.

Main TypesFire / Volume / Backdraft / Smoke
ActuationManual / Electric / Interlocked
DimensionsMatched to ductwork and project drawings
05 / Ductwork

Galvanized Steel Ductwork

Galvanized steel ductwork for cleanroom supply and return air, with smooth internal surfaces to reduce dust accumulation and optional insulation.

MaterialGalvanized steel
InsulationInternal / external insulation optional
ConnectionFlanged connection
06 / Filters

Pre / Medium / HEPA Filter Set

Three-stage filtration progressively captures particles to protect terminal HEPA air quality and extend filter service life.

Filter GradesG4 / F8 / H13
Replacement CycleBased on differential-pressure monitoring
Compatible EquipmentAHU / FFU
Applications

Applications

The HVAC system is central to cleanroom cleanliness and pressure control and should be designed together with the envelope and process layout.

Pharmaceutical GMP cleanroomSemiconductor wafer facilityBiosafety laboratoryFood aseptic filling areaHospital operating departmentProcess exhaust & waste-air systems

Need HVAC design support?

Provide room area, cleanroom class and process exhaust requirements, and we can assist with airflow calculations and equipment selection.

Contact Us for a Solution